Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
World Neurosurg ; 134: e353-e359, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31634624

RESUMO

OBJECTIVE: The aim of this study was to investigate the structural and functional changes in the visual cortex in patients with suprasellar tumor with recovery of visual field defects at different times before and after surgical decompression of the optic nerves. METHODS: Twenty-one patients with suprasellar tumor with visual field defects were scanned with structural images and resting-state functional magnetic resonance imaging at 1 week preoperation, 1 week postoperation, and 1 month postoperation. Paired-sample t test was performed on the gray matter volume (GMV) within the occipital cortex, and the significance level was set at false discovery rate (FDR)-adjusted P < 0.05 voxel level to define the region of interest (ROI). One-way analysis of variance was performed on GMV and amplitude of low frequency fluctuation (ALFF) within the ROI. Pearson coefficients were calculated between changes of GMV and ALFF within the ROI and clinical factors. RESULTS: The GMV in the bilateral pericalcarine cortex increased significantly at 1 month postoperation compared with the preoperative period (FDR-adjusted P < 0.05), with correlation to visual field defects. ALFF values in the bilateral pericalcarine cortex at 1 month postoperation were significantly higher than preoperative values. CONCLUSIONS: The postoperative visual improvement can be reflected in the increased GMV and ALFF of the bilateral pericalcarine cortex at 1 month postoperation, which suggests that an experience-dependent plasticity of the visual cortex was induced by an increase in sensory input.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Transtornos da Visão/diagnóstico por imagem , Córtex Visual/diagnóstico por imagem , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Neoplasias Encefálicas/cirurgia , Criança , Descompressão Cirúrgica/métodos , Descompressão Cirúrgica/tendências , Feminino , Humanos , Imageamento por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Transtornos da Visão/cirurgia , Córtex Visual/cirurgia , Testes de Campo Visual/métodos , Testes de Campo Visual/tendências , Campos Visuais/fisiologia , Adulto Jovem
3.
Ophthalmology ; 124(12S): S71-S75, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28865878

RESUMO

Visual field testing has played an essential role in the diagnosis and management of glaucoma for more than a century. Methods to examine the visual field have been refined from early kinetic perimetry to current standard automated perimetry (SAP). Clinicians now use SAP for the diagnosis and management of glaucoma throughout the world. Various testing paradigms and analytic methods have been developed to simplify the diagnosis of glaucoma and the interpretation of progression. Moreover, strategies have been implemented to improve patient experience with visual field testing and to increase reliability. Objective functional tests, such as electroretinography, provide an alternative to subjective visual field testing but are not yet ready for widespread adoption. Standard automated perimetry is being adapted and improved constantly. New devices may allow patients to complete visual field tests at home, which could relieve patients and clinicians from in-office testing and allow for more frequent examinations. Glaucoma detection and progression analysis also are incorporating progressively more information and will be improved as deep learning strategies are applied. Finally, perimetric and structural testing likely will become more closely intertwined as testing platforms and progression analysis incorporate both of these measures. Visual field testing will continue to have an important role in the diagnosis and management of glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/tendências , Campos Visuais , Humanos
4.
Invest Ophthalmol Vis Sci ; 55(1): 612-24, 2014 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-24408977

RESUMO

PURPOSE: To improve the detection of glaucoma, techniques for assessing local patterns of damage and for combining structure and function were developed. METHODS: Standard automated perimetry (SAP) and frequency-domain optical coherence tomography (fdOCT) data, consisting of macular retinal ganglion cell plus inner plexiform layer (mRGCPL) as well as macular and optic disc retinal nerve fiber layer (mRNFL and dRNFL) thicknesses, were collected from 52 eyes of 52 healthy controls and 156 eyes of 96 glaucoma suspects and patients. In addition to generating simple global metrics, SAP and fdOCT data were searched for contiguous clusters of abnormal points and converted to a continuous metric (pcc). The pcc metric, along with simpler methods, was used to combine the information from the SAP and fdOCT. The performance of different methods was assessed using the area under receiver operator characteristic curves (AROC scores). RESULTS: The pcc metric performed better than simple global measures for both the fdOCT and SAP. The best combined structure-function metric (mRGCPL&SAP pcc, AROC = 0.868 ± 0.032) was better (statistically significant) than the best metrics for independent measures of structure and function. When SAP was used as part of the inclusion and exclusion criteria, AROC scores increased for all metrics, including the best combined structure-function metric (AROC = 0.975 ± 0.014). CONCLUSIONS: A combined structure-function metric improved the detection of glaucomatous eyes. Overall, the primary sources of value-added for glaucoma detection stem from the continuous cluster search (the pcc), the mRGCPL data, and the combination of structure and function.


Assuntos
Algoritmos , Glaucoma/diagnóstico , Testes de Campo Visual/tendências , Campos Visuais , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Curva ROC , Reprodutibilidade dos Testes , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/tendências , Testes de Campo Visual/métodos
5.
Ophthalmologe ; 110(2): 107-15, 2013 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-23392836

RESUMO

We present a review and update on Pulsar perimetry, which combines temporal frequency, contrast and spatial frequency stimuli. The effects of age, visual acuity, and learning on results are described. Data on threshold fluctuation, signal-to-noise ratio, and the possibility of reducing noise with filtering techniques are provided. We describe its dynamic range and the possibility of compensating for profound defects. Finally, we show the results obtained in normal patients and in those with ocular hypertension or initial glaucoma, as well as an analysis of glaucoma progression.


Assuntos
Fusão Flicker , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Estimulação Luminosa/métodos , Testes de Campo Visual/métodos , Campos Visuais , Humanos , Estimulação Luminosa/instrumentação , Testes de Campo Visual/instrumentação , Testes de Campo Visual/tendências
6.
Ophthalmologe ; 110(2): 131-40, 2013 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-23392838

RESUMO

The selective perimetry with the FDF flicker stimulation has proven to be effective in a sample of 131 eyes in detecting early glaucomatous alterations, frequently without detectable changes in standard automated perimetry (SAP). Probability values may be successfully used as a new ordinal score of abnormality, especially for such marginal changes. Subjects must be thoroughly introduced to this new form of stimulation. The correlation of global perimetric with optic disc parameters is limited but slightly higher for FDF than for SAP. Interpretation thus requires an individual approach. In advanced cases SAP is preferable due to its larger dynamic range offered by the same instrument.


Assuntos
Fusão Flicker , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Estimulação Luminosa/métodos , Testes de Campo Visual/métodos , Campos Visuais , Humanos , Estimulação Luminosa/instrumentação , Testes de Campo Visual/instrumentação , Testes de Campo Visual/tendências
8.
Curr Diabetes Rev ; 8(3): 200-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22429015

RESUMO

Diabetic retinopathy is one of the leading causes of vision loss worldwide. Fluorescein angiogram still plays a primary role in its diagnosis but new non-invasive technologies as optical coherence tomography, fundus autofluorescence and microperimetry are gaining popularity in the last years. Anatomical changes found with these devices have been widely described but their correlation with visual function needs to be assessed and several features have been proposed as indicators of visual prognosis. The aim of this paper is to give a scope of the actual role of these techniques in the evaluation of retinal impairment secondary to diabetes.


Assuntos
Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Retinopatia Diabética/diagnóstico , Angiofluoresceinografia , Tomografia de Coerência Óptica , Testes de Campo Visual , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/fisiopatologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/fisiopatologia , Retinopatia Diabética/etiologia , Retinopatia Diabética/fisiopatologia , Feminino , Angiofluoresceinografia/métodos , Angiofluoresceinografia/tendências , Fundo de Olho , Humanos , Masculino , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/tendências , Acuidade Visual , Testes de Campo Visual/métodos , Testes de Campo Visual/tendências , Campos Visuais
9.
Ophthalmology ; 119(4): 748-58, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22218146

RESUMO

PURPOSE: To assess trends in the use of ancillary diagnostic tests in the evaluation of patients with open-angle glaucoma (OAG) and glaucoma suspects over the past decade. DESIGN: Retrospective, longitudinal cohort analysis. PARTICIPANTS: A total of 169 917 individuals with OAG and 395 721 individuals with suspected glaucoma aged ≥40 years enrolled in a national United States managed care network between 2001 and 2009. METHODS: Claims data were analyzed to assess trends in visual field (VF) testing, fundus photography (FP), and other ocular imaging (OOI) testing for patients with OAG or suspected glaucoma between 2001 and 2009. Repeated-measures logistic regression was performed to identify differences in the odds of undergoing these procedures in 2001, 2005, and 2009 and whether differences exist for patients under the exclusive care of optometrists versus ophthalmologists. MAIN OUTCOME MEASURES: Odds and annual probabilities of undergoing VF testing, FP, and OOI for OAG from 2001 to 2009. RESULTS: For patients with OAG, the odds of undergoing VF testing decreased by 36% from 2001 to 2005, by 12% from 2005 to 2009, and by 44% from 2001 to 2009. By comparison, the odds of having OOI increased by 100% from 2001 to 2005, by 24% from 2005 to 2009, and by 147% from 2001 to 2009. Probabilities of undergoing FP were relatively low (13%-25%) for both provider types and remained fairly steady over the decade. For patients cared for exclusively by optometrists, the probability of VF testing decreased from 66% in 2001 to 44% in 2009. Among those seen exclusively by ophthalmologists, the probability of VF testing decreased from 65% in 2001 to 51% in 2009. The probability of undergoing OOI increased from 26% in 2001 to 47% in 2009 for patients of optometrists and from 30% in 2001 to 46% in 2009 for patients of ophthalmologists. By 2008, patients with OAG receiving care exclusively by optometrists had a higher probability of undergoing OOI than VF testing. CONCLUSIONS: From 2001 to 2009, OOI increased dramatically whereas VF testing declined considerably. Because OOI has not been shown to be as effective at detecting OAG or disease progression compared with VF testing, increased reliance on OOI technology, in lieu of VF testing, may be detrimental to patient care.


Assuntos
Técnicas de Diagnóstico Oftalmológico/tendências , Glaucoma de Ângulo Aberto/diagnóstico , Oftalmologia/tendências , Optometria/tendências , Padrões de Prática Médica/tendências , Feminino , Angiofluoresceinografia/tendências , Seguimentos , Humanos , Masculino , Programas de Assistência Gerenciada/estatística & dados numéricos , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Razão de Chances , Estudos Retrospectivos , Tomografia de Coerência Óptica/tendências , Estados Unidos/epidemiologia , Testes de Campo Visual/tendências
10.
Arch Ophthalmol ; 129(12): 1521-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21825177

RESUMO

OBJECTIVE: To explore whether increased frequency of visual field testing leads to earlier detection of glaucoma progression with trend analyses. METHODS: The visual fields of 468 eyes (381 patients) from the Advanced Glaucoma Intervention Study with 10 or more reliable visual field tests and 3 or more years of follow-up were studied. Starting at year 1, every other visual field examination was deleted to create a low-frequency data set, and the original group was kept as the high-frequency data set. The proportion of progressing eyes and the time to progression were compared between the 2 data sets with global and pointwise linear regression criteria. RESULTS: The median number of visual field examinations was 20 and 12 for the high- and low-frequency data sets, respectively. Based on primary mean deviation criteria, 204 eyes (43.6%) in the high-frequency data set and 160 eyes (34.2%) in the low-frequency data set progressed (P < .001), whereas 185 eyes (39.5%) in the high-frequency data set and 167 eyes (35.7%) in the low-frequency data set progressed according to pointwise linear regression (P = .02). The high-frequency data set was more likely to detect progression with mean deviation (hazard ratio [HR], 1.69 [95% confidence interval {CI}, 1.36-2.10]) or pointwise linear regression criteria (HR, 1.52 [95% CI, 1.21-1.90]). A similar number of improving eyes were detected with mean deviation criteria (HR, 0.95 [95% CI, 0.58-1.60]), but pointwise linear regression criteria were more likely to detect improvement in the high-frequency data set (HR, 2.27 [95% CI, 1.43-3.62]). The results did not significantly change after censoring data at 5 years. CONCLUSIONS: Increasing the frequency of visual field testing leads to earlier detection of glaucoma progression, especially with global trend analyses. This finding has significant implications for the care of patients with glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/tendências , Campos Visuais , Idoso , Progressão da Doença , Diagnóstico Precoce , Feminino , Seguimentos , Humanos , Pressão Intraocular , Masculino , Modelos de Riscos Proporcionais
11.
Arch. Soc. Esp. Oftalmol ; 86(4): 113-117, abr. 2011. graf
Artigo em Espanhol | IBECS | ID: ibc-92519

RESUMO

Objetivo: Los umbrales normales de la perimetría Pulsar caen más rápidamente en el campoperiférico que los estándar. Se han realizado dos estudios relacionados, en primer lugar seha investigado la distribución de frecuencias de los defectos glaucomatosos en perimetríaautomática estándar (SAP), y la relación de los periféricos con los centrales (estudio A). Acontinuación se han tratado de definir los límites de examen Pulsar (estudio B).Material y métodos: Estudio A: las frecuencias se calcularon en 78.663 perimetrías SAP (G1-TOP, Octopus 1-2-3, Haag-Streit). Estudio B: 204 ojos con defecto medio (MD-SAP) inferiora 9 dB se examinaron 8,92±4,19 veces con SAP (TOP-32, Octopus 311) y con perimetría demodulación temporal (T30W, Perímetro Pulsar, Haag-Streit).Resultados: Estudio A: el 50,7% de los estudios SAP presentaron valores de MD inferiores a9 dB y el 32,7% inferiores a 6 dB. La correlación delMDde los 20◦ centrales con respecto alMDde los más periféricos fue de r = 0,933. Estudio B: en los casos con valores de MD-TOP-32 inferioresa 6 dB, SAP alcanzó sus posibilidades máximas de detección de defecto en el 0,02% delos puntos y Pulsar en el 0,29%. En los sujetos con MD-TOP-32 situado entre 6 y 9dB las frecuenciasfueron 0,38% en SAP y 3,5% en Pulsar (5,1% para excentricidades superiores a 20◦).Conclusiones: Pulsar permite detectar defectos, sin limitación de rango, en la mitad inicialde las frecuencias de defecto SAP esperables en el paciente glaucomatoso. Para estudiar laprogresión de defectos más profundos el análisis deberá centrarse en los puntos centrales,donde el rango dinámico de ambos sistemas es más equivalente(AU)


Objectives: Normal thresholds on Pulsar perimetry fall faster than those of standard perimetryin the peripheral visual field. Two related studies were performed. Firstly, the frequencydistributions of glaucoma defects on standard automated perimetry (SAP) and the relationshipof the centre and periphery (Study A) were studied first, followed by an attempt toestablish the limits of pulsar perimetry (Study B).Material and method: A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than9 dB were examined 8.92±4.19 times with SAP (TOP-32, Octopus 311) and temporal modulationperimetry (T30W, Pulsar Perimeter, Haag-Streit).Results: StudyA: 50.7% of the SAP examinations showedMDvalues lower than 9 dB and 32.7%bellow 6 dB. The MD correlation of the central 20◦ with the MD of the most peripheral pointswas r = 0.933. Study B: in cases with MD-TOP-32 lower than 6 dB, SAP had the maximumpossibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MDTOP-32 between 6 and 9 dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% foreccentricities higher than 20◦).Conclusions: Pulsar allows detecting defects, without range limitations, in the initial half ofSAP frequencies expected on glaucoma patients. In order to study the progression of deeperdefects the examination should focus on the central points, where the dynamic range ofboth systems is more equivalent(AU)


Assuntos
Humanos , Masculino , Feminino , Testes de Campo Visual/classificação , Testes de Campo Visual/métodos , Testes de Campo Visual/tendências , Glaucoma/diagnóstico
12.
J Glaucoma ; 20(4): 203-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20520567

RESUMO

PURPOSE: Visual field trend analysis can be influenced by outlying values that may disproportionately affect estimation of the rate of change. We tested a modified approach to visual field trend analysis to minimize this problem. METHODS: Automated pointwise linear regression (PLR) was used in glaucoma patients with ≥13 SITA-Standard 24-2 VF tests in either eye. In the control group (Group A), conventional PLR using the entire set of VF tests was carried out. In the other 3 groups (study groups), a truncated analysis was done using only the first and last 3 (Group B), first and last 4 (Group C), or first and last 5 (Group D) VF tests. We compared the global slopes (dB/y), number of eyes experiencing significant progression, and significant improvement between groups. RESULTS: Ninety eyes of 90 patients were evaluated. The mean number±SD of VF tests was 15.7±2.6, spanning 7.8±1.7 years. The study groups showed similar global rates of VF change as the control group (Group A=-0.48±0.5, Group B=-0.48±0.6, Group C=-0.48±0.6, Group D=-0.48±0.5 dB/y, P>0.05), and a similar number of eyes reaching a progression endpoint (Group A=53, Group B=52, Group C=49, Group D=53, P>0.05). However, Group B showed fewer eyes presenting VF improvement (false-positives). CONCLUSIONS: The modified VF trend-analysis showed greater specificity than conventional PLR in a population with glaucoma.


Assuntos
Glaucoma/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/tendências , Campos Visuais , Progressão da Doença , Reações Falso-Positivas , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Transtornos da Visão/fisiopatologia
13.
Optom Vis Sci ; 88(1): E8-15, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21131878

RESUMO

Perimetry and visual field testing have been used as clinical ophthalmic diagnostic tools for many years, and this manuscript will provide a brief historical overview of these procedures and the individuals who developed them. Today, we have many different forms of perimetry that are designed to evaluate different locations within the visual pathways and various mechanisms and subsets of mechanisms within the visual system. However, the most widely used method of performing perimetry and visual field testing has not substantially changed for more than 150 years, consisting of detecting a small target superimposed on a uniform background at different locations within the field of view. Although the basic test procedure has remained similar throughout the ages, there have been many advances in test administration, standardization, statistical evaluation, clinical analysis, interpretation, and prediction of outcome based on visual field findings.


Assuntos
Testes Visuais/história , Testes de Campo Visual/história , Campos Visuais , Automação , História do Século XVII , História do Século XIX , História do Século XX , História Antiga , Humanos , Testes Visuais/instrumentação , Testes Visuais/métodos , Testes de Campo Visual/instrumentação , Testes de Campo Visual/métodos , Testes de Campo Visual/tendências
14.
Ophthalmologe ; 106(8): 709-13, 2009 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-19652980

RESUMO

Glaucoma is a disease in which death of retinal ganglion cells is associated with loss of visual function. The gold standard for visual field testing has been standard automated perimetry (SAP). However, up to 30-50% of retinal ganglion cells must be lost before a scotoma is detected with SAP. Therefore, investigators have been interested in finding diagnostic techniques that would allow earlier detection of visual field loss than that detected by standard white-on-white perimetry. Frequency-doubling technology (FDT) has been suggested as a promising technique that may detect glaucomatous ganglion cell damage earlier than SAP by targeting a sparsely spaced subsystem of Mgamma retinal ganglion cells where cell damage is less masked by redundancy. The second generation of FDT perimetry, the Matrix FDT, was released with the intention of improving the spatial resolution of visual field defects. In this article we present FDT and discuss data that compare FDT with standard white-on-white perimetry.


Assuntos
Glaucoma/complicações , Glaucoma/diagnóstico , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia , Testes de Campo Visual/instrumentação , Testes de Campo Visual/métodos , Campos Visuais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Testes de Campo Visual/tendências
16.
Fisioterapia (Madr., Ed. impr.) ; 30(6): 268-272, nov.-dic. 2008. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-61215

RESUMO

Este estudio presenta los efectos conseguidos por la electroporación en la lipólisis abdominal utilizando la vehiculación de la fosfatidilcolina (fosfolípido que facilita la absorción de las grasas). Se llevó a cabo en 10 mujeres voluntarias, nulíparas, sedentarias, con una edad media de 25,10 años e índice de masa corporal entre 18,5 y 25 kg/m2. Recibieron 15 sesiones de tratamiento fisioterápico, constando esta de una aplicación tópica de fosfatidilcolina al 10% liposomada en el abdomen con electroporación. La técnica consistió en colocar el transductor del equipo en la pared abdominal emitiendo ondas electromagnéticas con un voltaje de 500 mV y una frecuencia de 50 Hz durante 30 minutos. Este tratamiento alcanzó una reducción del tejido adiposo subcutáneo de la pared abdominal, comprobada por medida perimétrica del abdomen, medida del pliegue cutáneo infraumbilical y por ultrasonografía. En la perimetría, la reducción media fue de 4,75 cm, en la plicometría de 2,43 mm y la ultrasonografía demostró una disminución del grosor del tejido adiposo que pasó de una media de 2,21 cm a 1,65 cm. Sin embargo, no se halló ninguna reducción ponderal significativa, aunque la disminución presentada en los tres métodos de evaluación sugiere que la utilización de la fosfatidilcolina con la electroporación puede desencadenar efectos lipolíticos(AU)


The present study presents the effects achieved with electroporation in abdominallipolysis using vehiculization of phosphatidylcholine (phospholipide that facilitates fatabsorption). The study was conducted in 10 voluntary women, nulliparous, sedentary women, with a mean age of 25.10 years and body mass index between 18.5 and 25 kg/m2.They were administered 15 sessions of physiotherapy, this being made up of a topicalapplication of 10% liposomal phosphatidylcholine in the abdomen with electroporation.The technique consisted in placing the equipment transductor on the abdominal wall,emitting electromagnetic waves with a 500mV voltage and 50 Hz frequency for 30 minutes.This treatment achieved a reduction of the subcutaneous adipose tissue of the abdominalwall, verified by perimetric measurement of the abdomen, measurement of infraumbilicalskin fold and by ultrasound. In the perimetry, the mean reduction was 4.75 cm, in theplicometry 2.43mm and the ultrasonograph showed a decrease of adipose tissue thicknessthat went from a mean of 2.21 cm to 1.65 cm. However, no significant weight reduction wasfound, although the decrease found in the three evaluation methods suggests that the useof phosphatidylcholine with electroporation may precipitate lipolitic effects(AU)


Assuntos
Humanos , Feminino , Adulto , Eletroporação/estatística & dados numéricos , Eletroporação/tendências , Eletroporação , Lipólise/fisiologia , Lipólise/efeitos da radiação , Fosfatidilcolina-Esterol O-Aciltransferase/uso terapêutico , Índice de Massa Corporal , Testes de Campo Visual/métodos , Modalidades de Fisioterapia/tendências , Modalidades de Fisioterapia , Eletroporação/classificação , Eletroporação/métodos , Parede Abdominal/fisiologia , Parede Abdominal , Testes de Campo Visual/instrumentação , Testes de Campo Visual/tendências , Estudos Transversais
17.
Arch. Soc. Esp. Oftalmol ; 83(8): 471-478, ago. 2008. ilus, tab
Artigo em Es | IBECS | ID: ibc-66872

RESUMO

Objetivos: Describir las manifestaciones visuales en neoplasias neuropediátricas, relacionarlas con la localización tumoral y analizar su relevancia en el seguimiento de la enfermedad. Material y métodos: Estudio descriptivo retrospectivo que incluye pacientes menores de 14 años con neoplasias cerebrales de cualquier estirpe, registradas en nuestro centro desde 1996 hasta el 2005. Resultados: En un 44% de los pacientes con descenso en la agudeza visual, la ambliopía fue catalogada como orgánica. En el 28% de los casos, la ambliopía era secundaria al estrabismo/nistagmus producido por el tumor. El tratamiento corrector resultó efectivo en varios casos de ambliopía parcial y totalmente orgánica. Tres recidivas tumorales fueron detectadas gracias a la exploración de fondo de ojo y campimetría, antes de que las pruebas de imagen fueran concluyentes. Conclusión: El examen oftalmológico (agudeza visual, campimetría, funduscopia) es una pieza clave en el seguimiento de la patología tumoral cerebral. Las ambliopías orgánicas parciales/totales son susceptibles de tratamiento corrector


Purposes: To describe the visual manifestations of brain neoplasms, and to analyze the effect of tumor control on these. Methods: This is a descriptive retrospective study, which includes patients under 14 years of age, suffering from different brain neoplasms in our hospital between 1996 and 2005 inclusive. Results: In the group of patients with low visual acuity, 44% had organic amblyopias. In 28% of cases, the amblyopia was secondary to the strabismus/nystagmus produced by the developing tumor. Corrective treatment was successful in some cases of partial or total organic amblyopia. Ophthalmologic evaluation (including perimetry and fundoscopy) enabled detection of 3 tumor relapses. Conclusions: Visual analysis (visual acuity, perimetry, fundoscopy) should be an essential component of assessment during brain neoplasm treatment and follow-up. Corrective treatment is sometimes successful in organic amblyopias (Arch Soc Esp Oftalmol 2008; 83: 471-478)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Criança , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/diagnóstico , Fundo de Olho , Testes de Campo Visual/métodos , Testes de Campo Visual/tendências , Astrocitoma/complicações , Astrocitoma/diagnóstico , Estudos Retrospectivos , Oftalmoscopia , Tomografia Computadorizada de Emissão
18.
Arch. Soc. Esp. Oftalmol ; 83(8): 505-508, ago. 2008. ilus
Artigo em Es | IBECS | ID: ibc-66878

RESUMO

Caso Clínico: Se presenta el caso clínico de un varón de 30 años con una distrofia foveomacular viteliforme del adulto bilateral simétrica, que de forma simultánea desarrolla una coriorretinopatía central serosa (CRCS) y en el que se aprecia la coexistencia de múltiples puntos blancos en la proximidad de las arcadas vasculares temporales. La angiografía fluoresceínica demuestra la alteración mixta de ambos tipos de fotorreceptores, así como la lesión aguda de la CRCS en el polo posterior OI. Discusión: La distrofia foveomacular del adulto es una alteración hereditaria del polo posterior que no suele evolucionar con complicaciones agudas. La aparición de una coriorretinopatía central no es habitual


Case report: The clinical case of a 30 year-old male patient with a bilateral and symmetric adult-onset foveomacular vitelliform dystrophy is presented. The simultaneous onset of a central serous chorioretinopathy (CSCR) with multiple white dots in the proximity of the temporal vascular arcades is documented. Fluorescein angiography showed a combined alteration of both types of photoreceptors, and the acute lesion of the CSCR at the posterior pole of the eye. Discussion: Adult-Onset Foveomacular Vitelliform Dystrophy is a hereditary condition which results in an alteration of the posterior pole of the eye, but is not usually associated with any acute complications. The onset of a CSCR, as seen in this case, is unusual 2008; 83: 505-508)


Assuntos
Humanos , Masculino , Adulto , Retinite Pigmentosa/complicações , Retinite Pigmentosa/diagnóstico , Células Fotorreceptoras/patologia , Células Fotorreceptoras , Degeneração Macular/diagnóstico , Degeneração Macular/terapia , Anamnese/métodos , Fundo de Olho , Angiofluoresceinografia/métodos , Testes de Campo Visual/métodos , Degeneração Macular/epidemiologia , Degeneração Macular/patologia , Angiofluoresceinografia/estatística & dados numéricos , Angiofluoresceinografia/tendências , Angiofluoresceinografia , Testes de Campo Visual/tendências , Testes de Campo Visual
19.
Optometry ; 79(7): 397-403, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18577497

RESUMO

BACKGROUND: The Amsler grid is a widely used means of evaluating the central 20 degrees diameter visual field. It is a common practice to have patients who are at risk for exudative maculopathy evaluate their macular function daily using the Amsler grid. The goal is to make the patient aware of the earliest symptoms of choroidal neovascularization at a time when therapeutic intervention has the greatest chance for success. There are, however, several important shortcomings of self-monitoring macular function with the Amsler grid, including low sensitivity and low compliance. METHODS: The history of macular function surveillance is reviewed. The following techniques that are either currently available or under development for home self-monitoring of macular function are discussed: Amsler grid, red Amsler grid, threshold Amsler grid, environmental Amsler techniques, entoptic perimetry, preferential hyperacuity perimetry, and Internet-based interventions. CONCLUSION: There is compelling evidence that several currently available technologies are superior to the conventional Amsler grid in detecting the earliest symptoms of macular disease. Threshold Amsler grid, entoptic perimetry, and preferential hyperacuity perimetry each have been found to be more sensitive than the conventional Amsler grid in detecting vision disturbances caused by macular disease. Any one of these diagnostic tests could conceivably be utilized by patients at home for self-monitoring of macular function if the technology were suitably deployed for this purpose, such as over the Internet.


Assuntos
Macula Lutea/fisiologia , Doenças Retinianas/fisiopatologia , Testes de Campo Visual/instrumentação , Humanos , Doenças Retinianas/diagnóstico , Testes de Campo Visual/tendências
20.
Arch. Soc. Esp. Oftalmol ; 82(11): 711-714, nov. 2007. ilus
Artigo em Es | IBECS | ID: ibc-056809

RESUMO

Caso clínico: Paciente epiléptico de 63 años en tratamiento con vigabatrina que refería déficit de agudeza visual. Presentaba una retinopatía tóxica con palidez papilar e importante retracción del campo visual. Tras un año de suspensión del tratamiento persistía la retracción campimétrica. Discusión: Neurólogos y oftalmólogos debemos concienciarnos del potencial efecto retinotóxico de la vigabatrina. No hay consenso en cuanto a la estrategia de screening a utilizar. Una evaluación campimétrica hasta los 60º y una tomografía óptica de coherencia (OCT) parecen ser test diagnósticos sensibles en el screening de pacientes que toman vigabatrina


Case report: We report a case of a 63-year-old patient with epilepsy treated with vigabatrin, who was seen because of diminished visual acuity. Examination showed a toxic retinopathy with optic nerve pallor and severely constricted visual fields. One year after cessation of the vigabatrin, no change in the perimetric constriction had occurred. Discussion: Ophthalmologists and neurologists need to be aware of the possibility of retinal toxicity due to the use of vigabatrin. It is still unclear as to which ophthalmogic assessment is of the most diagnostic value; however visual field examination covering the peripheral 60º and optical coherence tomography could be most useful for the screening of patients using this agent


Assuntos
Masculino , Pessoa de Meia-Idade , Humanos , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Diabetes Mellitus/complicações , Carbamazepina/efeitos adversos , Carbamazepina/uso terapêutico , Vigabatrina/efeitos adversos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica , Testes de Campo Visual/tendências , Testes de Campo Visual , Vigabatrina/uso terapêutico , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...